Baumer HUBNER POG 10 G Series 설치 및 작동 지침 - 페이지 7
{카테고리_이름} Baumer HUBNER POG 10 G Series에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer HUBNER POG 10 G Series 32 페이지. Incremental encoder (twin encoder)
Baumer HUBNER POG 10 G Series에 대해서도 마찬가지입니다: 설치 및 운영 지침 매뉴얼 (36 페이지), 설치 및 작동 지침 (36 페이지), 설치 및 작동 지침 (32 페이지), 설치 및 작동 지침 (28 페이지)
2
Operation in potentially explosive environments (only with option ATEX)
The device complies with the directive 2014/34/EU for potentionally explosive atmospheres.
It can be used in accordance with equipment categories 3 G (explosive gas atmosphere) and
3 D (explosive dust atmosphere).
Equipment category 3 G: - Ex labeling:
Equipment category 3 D:
The operation in other explosive atmospheres is not permissible.
2.1
In Ex areas the device must only be used within the ambient temperature range from -20 °C to
+40 °C.
2.2
The plant operator must ensure that any possible dust deposit does not exceed a thickness of
5 mm (in accordance with EN 60079-14).
2.3
An UL listing that may be stated elsewhere is not valid for use in explosive environments.
2.4
Operation of the device is only permissible when ...
– the details on the type label of the device match the on-site conditions for the permissible
Ex area in use (group of equipment, equipment category, zone, temperature class or maxi-
mum surface temperature),
– the details on the type label of the device match the electrical supply network,
– the device is undamaged (no damage resulting from transport or storage), and
– it has been checked that there is no explosive atmosphere, oils, acids, gases, vapors,
radiation etc. present when mounting.
2.5
It is not permissible to make any alteration to equipment that is used in potentially explosive en-
vironments. Repairs may only be carried out by authorized authorities provided by the manufac-
turer. Contravention invalidates the EX approval.
2.6
Attend the norm EN 60079-14 during mount and operation.
The device must be operated in accordance with the stipulations of the mounting and
operating instructions. The relevant laws, regulations and standards for the planned
application must be observed.
MB069aT1 - 11055672
Baumer_POG10-B3_T1_DE_EN_202202_MI_11055672 (22A1)
Operation in potentially explosive environments
- Conforms to standard:
- Type of protection:
- Temperature class:
- Group of equipment:
- Ex labeling:
- Conforms to standard:
- Protective principle:
- Max. surface temperature:
- Group of equipment:
II 3 G Ex ec IIC T4 Gc
EN IEC 60079-0:2018
EN IEC 60079-7:2015 +A1:2018
ec
T4
II
II 3 D Ex tc IIIC T135°C Dc
EN 60079-31:2014
Protection by enclosure
+135 °C
III
2
4