Baumer Hubner POG 9 설치 및 작동 지침 - 페이지 29
{카테고리_이름} Baumer Hubner POG 9에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer Hubner POG 9 32 페이지. Incremental encoder
9
Technical data
9.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
9.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Flange:
• Protection EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
5)
MB068T1 - 11055668
9...30 VDC
5 VDC ±5 % (TTL)
≤100 mA
300...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz, ≤300 kHz option
K1, K2, K0 + inverted, error output (option EMS)
HTL-P (power linedriver), TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E217823
ø115 mm
ø11 mm solid shaft
≤250 N axial, ≤350 N radial
EURO flange B10
IP56
≤12000 rpm (mechanical)
2 Ncm
200 gcm
Housing: aluminium die-cast, shaft: stainless steel
-30...+100 °C
-25...+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 300 g, 1 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
(only with option ATEX)
Terminal box (option G: 2x)
1.4 kg, 2 kg (option G)
Baumer_POG9-POG9G-T1_DE_EN_202109_MI_11055668 (21A2)
(HTL-P, TTL - version R)
5)
2
Technical data
9
26