5
Montage / Mounting
5.11

Schritt 9 - Klemmenkasten

Buchse D-SUB
zum Anschluss an
Drehgebergehäuse
siehe Abschnitt 5.12.
Connector D-SUB (female)
for connecting to
encoder housing
see section 5.12.
5.12

Schritt 10 - Klemmenkasten

TX 20
Zul. Anzugsmoment
Max. tightening torque
M
= 2-3 Nm
t
* Siehe Seite 7
See page 7
Vor der Montage des Klemmenka-
stendeckels prüfen, ob die Klemmen-
kastendeckeldichtung unbeschädigt
ist.
15
*
5
*
4
Baumer_POG11-POG11G-T1_II_DE-EN (16A4)
5.11

Step 9 - Terminal box

*
8
*
7
9 *
*
15
5.12

Step 10 - Terminal box

*
9
Check that the seal of the terminal
box is not damaged before mounting
the terminal box.
TX 10
22 mm
Großer, um 180°
wendbarer Klemmenkasten.
Big terminal box,
turn by 180°.
MB070T1 - 11055673