3.5.2. Detailed object description

Object 1000
Device Type
Subindex
Data Type
Access
Default
EEPROM
Description
Values
Object 1001
Error Register
Subindex
Data Type
Access
Default
EEPROM
Description
Values
Object 1003
Predefined Error Field
Here CiA (CAN in Automation) defines approximately 200 different Error Codes.
This document only describes the Error Codes relevant for the sensor.
This object saves the last 8 errors or warnings which have occurred.
Subindex
Data Type
Access
Default
EEPROM
Description
Values
Subindex
Data Type
Access
Default
EEPROM
Description
Values
Manual_GXP5_417_Lift_EN.doc
04.05.11
0
Unsigned 32
ReadOnly
060001A1h
No
Information on device profile and device model
0
15
2
..2
Profile No.= 1A1h=417 (Application Profile for Lift Control
Systems).
16
23
2
..2
Communication model
24
31
2
..2
Virtual device code
0
Unsigned 8
ReadOnly
0h
No
Current Error Code
Bit 0
1 = Generic Error
0
Unsigned 8
ReadWrite
0
No
Read: Number of errors or warnings
Write 0: Reset errors
0 - 8
1..8
Unsigned 32
ReadOnly
0
No
Errors or warnings which have occurred, whereby Subindex 1 is the last
entry, Subindex 2 the next to the last etc.
Not yet defined
20/41
Baumer IVO GmbH & Co. KG