Object 2800
PDO1 Addition (Event Trigger)
Subindex
Data Type
Access
Default
EEPROM
Description
Values
Manual_GXP5_417_Lift_EN.doc
04.05.11
0
Unsigned 8
ReadWrite
0h
Yes
Event Trigger value determines how often same PDO value is
transmitted
0 =
PDO counter is deactivated
basis from Event Timer)
1..n..255 = Same PDO value is transmitted n times
(time basis from Event Timer)
constant transmission (time