3.5 Sensor zeroing

The inclination sensors with the measuring ranges 0...90°, 0...120°, 0...180° and 0...270° have the function
zero setting. By zeroing the output value at the defined position corresponds to an inclination of 0°.
To execute zeroing, apply a HIGH signal (≥ 0.7 * Vs ) pin 5 (teach input) for >250 ms (see 4.1 Electrical
connection)
2-dimensional sensors apply the zeroing operation to both directions X/Y).
1-dimensional:
+ 45°
2-dimensional - horizontal installation:
Y axis
X axis
- 45°
- 45°
2-dimensional - vertikal installation:
X axis
Y axis
+ 45°
- 45°