Baumer CleverLevel PL20H/S 사용 설명서 - 페이지 14

{카테고리_이름} Baumer CleverLevel PL20H/S에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer CleverLevel PL20H/S 44 페이지. Level measurement adaptive trigger – hygienic/industrial

Baumer CleverLevel PL20H/S 사용 설명서
CleverLevel
Adaptive trigger – hygienic/industrial
14.3 Window trigger
The window trigger is used to cause a sensor switch to react within a specific range, for example, in order
to isolate a specific medium. The switching window can be configured within a range from 0 ... 100 %. The
window trigger is recommended for detecting and separating different layers, for example oil from water or
foam from beer.
I
Signal (%)
1
2
3
0
20
50
1
Good conductive medium
2
Adhesion from good conductive adhesive
medium
3
Oily medium
4
Air
14.4 LED factory settings
LED-Funktion*
SW1
SW2
0
0
1
0
0
1
1
1
Error
Error
Short circuit Short circuit
*1 = active, 0 = inactive
14 / 44
Level measurement
®
PL20H/S
II
4
80
100
Sweep Range (%)
LED color
Green
Yellow
Cyan
Blue
Flashing red
Red
Operating Instructions
Configuration example for a vessel that can be
filled with either a good conductive adhesive
medium (e.g. fruit preparation) or with an oily
medium (e.g. chocolate mix).
Switch windows I and II in this example are set to
achieve the following goals:
to detect the fruit preparation (1)
„
to exclude adhesion from fruit preparation (2)
„
to identify the chocolate mixture (3)
„
For more information, refer to the HELP menu in
FlexProgram.
Window trigger – Output setup
SW1 (NO) / SW2 (NO)
Switch window, min.
Switch window, max.
Switch window, hysteresis
Damping
Color examples
YE
YE = Yellow: SW1 aktiv
„
CY = Cyan: SW2 aktiv
„
BU = Blue: SW1 und SW2 aktiv
„
GN = Green: SW1 und SW2 inaktiv
„
Factory setting
0%
75,3%
2,4%
0,1 s
CY
BU
www.baumer.com
GN