Baumer OM30 운영 매뉴얼 - 페이지 39
{카테고리_이름} Baumer OM30에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer OM30 48 페이지. Laser distance sensors
Baumer
9.3
Exposure reserve
The exposure reserve indicates the light quantity reflected by the measurement object (as a rel-
ative factor without unit). The exposure reserve helps you with the following problems, among
others:
Check whether a valid measurement result is present (signal quality). The signal quality is
n
weak
▪ when the sensor is not optimally aligned, and
▪ when the distance between the sensor and measurement object is too large.
During ongoing operation: Check the front panel of the sensor for soiling – if the exposure
n
reserve decreases over time, it may be an indication of increased soiling of the front panel.
Use the histogram function for this purpose
IO-Link diagnostic data: Exposure reserve
Name
Exposure Reserve. Exposure Reserve
9.4
Signal quality
The signal quality serves as an indication of the reliability of the measurement.
IO-Link diagnostic data: Signal quality
Name
Exposure Reserve.Quality
Level
OM20/OM30 | V1
(Histogram function
Description
Output of the exposure reserve.
Description
Output of the signal quality.
n
▪ 0 = Valid signal
▪ 1 = Weak signal
Low signal quality can result in greater measured value er-
rors. Decrease the distance to the measurement object or
optimize the alignment of the sensor.
▪ 2 = Critical signal
Valid measured value acquisition is no longer guaranteed.
Decrease the distance to the measurement object or opti-
mize the alignment of the sensor.
LEDs blink if a critical signal is reached.
The alarm output is activated when no measured value can
be recorded anymore.
Operating Manual
Diagnostic data
[} 41]).
|
9
39