3

Security

WARNING
Danger caused by leaking system
Sensor installation in pipe systems may cause leaks. Such leaks may cause a great number of
hazards.
Therefore, it is imperative to observe the following during sensor mount:
a) Only use welding sleeves and adapters from Baumer.
b) Always check seals for damage and cleanliness.
c) The welding should only be carried out by persons who are trained in the hygiene sector.
d) Never seal process connections with Teflon tape (PTFE) or elastomer.
NOTICE
Risk of damage to equipment by contamination
Contamination may penetrate into the system and result in material damage.
a) Always cover exposed system parts before carrying out any work, e.g. drilling.
b) Immediately collect any dust and chips produced during installation work.
NOTICE
Damage to seal or push-in fitting
Excessive tightening of the union nut may damage the connection or the O-seal provided at the
M12 cable.
a) Tighten the union nut to a maximum torque of 0.6 Nm.
b) Never use any tools to tighten the union nut.
INFO
Weld-in sleeves or adapters in hygienic applications
It is recommended to use weld-in sleeves or adapters for sensor installation.
Observe the following:
a) 3-A mark or arrow must point upward.
b) The leakage hole must point downwards.
c) Hygienically and internally flush.
d) Grind welding to Ra ≤ 0.8.
V1 | PAC50H/S
Operating Manual
Security
|
3
7