Baumer HUBNER BERLIN GT5 설치 및 작동 지침 - 페이지 18
{카테고리_이름} Baumer HUBNER BERLIN GT5에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer HUBNER BERLIN GT5 20 페이지. Tachogenerator
9
Technical data
9
Technical data
9.1
Technical data - electrical ratings
• Reversal tolerance:
• Linearity tolerance:
• Temperature coefficient:
• Isolation class:
• Calibration tolerance:
• Climatic test:
• Performance:
• Armature-circuit time-constant (τ
• Open-circuit voltage:
• Interference immunity:
• Emitted interference:
• Approval:
9.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Protection DIN EN 60529:
• Torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Weight approx.:
• Connection:
15
≤0.1 %
≤0.15 %
±0.005 %/K (open-circuit)
B
±5 %
Humid heat, constant
(IEC 60068-2-3, Ca)
0.075 W (speed ≥5000 rpm)
):
<4.5 µs
A
7...10 mV per rpm (as ordered)
EN 61000-6-2
EN 61000-6-3
CE
ø52 mm
ø8...12 mm (blind hollow shaft)
IP00
IP44 (with cover and plug-in terminals)
IP54 (with cover and cable gland)
0.3 Ncm
0.05 kgcm
2
Housing: stainless steel / plastic
Shaft: stainless steel
-30...+130°C
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
150 g
Plug-in terminals
Baumer_GT5_II_DE-EN (19A1)
MB021 - 11055625