The dispenser must be connected to
the drinking water system and to the
electric system following local
regulations. Check whether the power
supply corresponds with the values
given on the rating plate. The
dispenser must be connected to an
electric circuit which is secured by an
extra fuse (for fuse data see the rating
plate). The connection must be made
using a safety plug socket earthed
according to the regulations.
Follow local regulations!
If the dispenser will not be used for a
longer period of time (e. g. at night or
during the weekend), close the water
cock. Switch the power switch to
"OFF". Do not pull out the power
supply plug because otherwise the
cooling system will not function any
more.
The dispenser must not be used when
the water supply is interrupted
because otherwise the boiler will not
be refilled.
12.03
Do not switch off the dispenser
between beverage deliveries in order
to keep the optimum water
temperature in the boiler.
Use only original spare parts.
If the dispenser is equipped with a
heating plate, do not touch it.
There is danger of being burned.
Before putting a glass pot onto the
heating plate, take care that it is
heatproof.
The dispenser may only be installed,
programmed and repaired by specially
trained service technicians who are fa-
miliar with the safety and hygiene as-
pects of the dispenser.

Safety Instructions

The dispenser may not be subject to
frost during operation, storage and
transport.
- In order to prevent damage due to
frost, the service technician must
completely drain the water from the
boiler prior to storage and transport
and must also remove any residual
water from hoses and valves.
- It is recommended to store and
transport the dispenser in its original
packaging.
- However, if there is the danger of
damage due to frost, the service
technician must check and replace
boiler, hoses and valves if required
prior to reconnecting the dispenser and
he should additionally carry out a
functional test.