6.

Electrical connection

6.1. Safety instructions for electrical connection
• Warning! Observe the additional safety precautions in chapter 4.
• Warning! Danger of electric shock!
Make sure tachogenerator is not live for the time of electrical commissio-
ning!
Switch off power supply of any equipment involved!
Ensure proper grounding!!
6.2. Electrical commissioning
• Connect protective earthing conductor to terminal M4-PE (ground).
• Remove terminal box cover (with the "Thalheim" label).
• Use a mating cable to connect terminal box at Pg7.
• Assign the terminals.
• A1 = + ; A2 = - at cw rotation
• Only use cables
recommended by Baumer.
• Close terminal box cover.
Shaft design as product combination:
KTD 3-... + ITD 2... B10; ITD 4.... + KTD 3-... B10...
• Connect cable respectively flange connector of the incremental encoder. For
terminal assignment please see data sheet.
7. Maintenance, repair & disposal
• Any repair work or opening of the tachogenerator by the manufacturer only.
• Dispose of all integrated components in compliance with the country-specific
provisions.