Baumer EX Series 사용자 설명서 - 페이지 26

{카테고리_이름} Baumer EX Series에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer EX Series 42 페이지. Gigabit ethernet
Baumer EX Series에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (2 페이지)

Baumer EX Series 사용자 설명서
Figure 34 ►
Timestamps of recorded 
images.
26

4.7 User Sets

Four user sets (0-3) are available for the Baumer cameras of the EXG series. User set 0 
is the default set and contains the factory settings. User sets 1 to 3 are user-specific and 
can contain the following information:
Parameter
Binning
Brightness Correction
Defect Pixel Correction
Defectpixellist
Flash Settings
Gain
Flash Settings
These user sets are stored within the camera and and cannot be saved outside the de-
vice. 
By employing a so-called "user set default selector", one of the four possible user sets 
can be selected as default, which means, the camera starts up with these adjusted pa-
rameters. 
4.8 Factory Settings
The factory settings are stored in "user set 0" which is the default user set. This is the only 
user set, that is not editable.

4.9 Timestamp

The  timestamp  is  part  of  the  GigE  Vision
Ticks
. Any image or event includes its corresponding timestamp. 
*)
At power on or reset, the timestamp starts running from zero.
*) Tick is the internal time unit of the camera, it lasts 32 nsec.
Parameter
Image Format
Look-Up-Table
Message Channel
Offset (Black Level)
Partial Scan
Pixel Format
Trigger Settings
  standard.  It  is  64  bits  long  and  denoted  in 
®
1123354
1123254
1123154
1123054
1122754
1122654
1122554
1122454
1122354