Baumer SXC10c 사용자 설명서 - 페이지 28

{카테고리_이름} Baumer SXC10c에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer SXC10c 48 페이지. Sxc series cameralink cameras with truesense imaging sensors
Baumer SXC10c에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (2 페이지)

Baumer SXC10c 사용자 설명서
Figure 21 ►
Partial Scan:
Read out Lines.
Figure 22 ►
Partial Scan:
Example  ROI's  with 
identical readout times.
Figure 23 ►
Partial Scan:
Read out time linked
with position of the ROI.
28
Pixel Information of Interrest
Discarted Pixel Information
The most significant reduction of the readout time – compared to a full frame readout in 
dual mode – can be achieved if the ROI is positioned as follows:
within one of the sensor halves
symmetrically spread to both sensor halves
For example, the readout time of the ROI's in the figures 21 and 22 is the same. 
On asymmetrically spread ROI's, the readout time is affected by the bigger part of the 
ROI.
An example for this fact is shown in the figure below:
The ROI has the same size as in figure 21, but is not symmetrically spread to both sen-
sor halves. In this special case the time for the readout of the same number of pixels is
increased by 50%, caused only by ROI's position.
ROI
Read out Lines