6.1.3. Readout Modes

The Truesense Imaging sensors, employed in Baumer SXC cameras, are subdivided into 
four Taps.
Due to Baumer's integrated calibration technique, these taps are invisible within the re-
corded images, but affect the operation and the rate of the readout process and therewith
the readout time (t
).
readout
6.1.3.1.
Quad Mode
On quad readout mode all four taps are read out simultaneously as displayed in the sub-
sequent figure.
The data of all pixels of one tap are moved to the output register and afterwards trans-
fered to the memory.
Once the information have left the output register, the readout is done. 
This mode provides the full potential of the sensor and leads to the maximum frame
rate.
6.1.3.2.
Dual Mode
On  dual  readout  mode  two  taps  (Tap 0 + Tap 2 and Tap 1 + Tap  3)  are  combined. 
The data of all pixels of one tap are moved to the output register and afterwards trans-
fered to the memory.
Once the information have left the output register, the readout is finished. 
Due to the fact, that more data needs to be read out, the t
the quad readout mode.
It is considered:  
t
 ≈ 2 × t
readout(Dual Mode)
is increased compared to
readout
readout(Quad Mode)
◄ Figure 7
Taps of the employed 
sensors.
◄ Figure 8
Quad Tap Readout
Mode.
◄ Figure 9
Dual Tap Readout
Mode.