Dove Lighting Systems DimmerMaster 사용자 설명서 - 페이지 8

{카테고리_이름} Dove Lighting Systems DimmerMaster에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dove Lighting Systems DimmerMaster 12 페이지. Wall mount dimmer packs

contact control terminal block. Each terminal is large enough to accommodate multiple signal
wires so the control signals can be easily daisy-chained from pack to pack. However, do not
create Ys in the DMX signal path as these can lead to signal integrity issues that result in
poor reliability and flickering. Instead, use one of the specialty interface boxes for this
purpose (for example, the Dove DMX-Y).
Terminals 4 and 5 are typically not used, but can be used to aid in splicing another pair of
signal wires like a second DMX universe. DIP switch 9 will connect Terminal 5 to +15V when
in the on position and should be loaded with less than 100mA. This is an unregulated power
source and will typically vary between 12 and 18 Volts. Under no-load conditions it can reach
25V. An example application of this feature would be to power a Dove DMX-Y.
Terminal 6 is +15VDC referenced to Common. This is an unregulated power source and will
typically vary between 12 and 18 Volts. Under no load conditions it can reach 25V. It will
typically source over 200mA before dropping below 12V. This source is typically used to
power the Dove 0-10V House Light Controls or our DMX-Y.
Terminals 7 through 10 are 0-10V analog control inputs for outputs 1 through 4 respectively.
(The DM124-WM ignores terminals 8 through 10.) The higher of the analog or DMX for a
given channel will take precedence (HTP). Terminal 11 is the common for these analog inputs
and therefore must be connected to the analog control source as well. It is also connected to
Terminal 1 internally.
Finally, Terminal 12 is the Force-On input. When this terminal is connected to common
(Terminals 1 & 11), all channels will be turned on to 100% overriding any DMX or Analog
control signals. The Wall Mount DimmerMasters' push-button option replaces the standard
Neon Power Indicator with a push-button connected to Terminals 11 & 12. One can easily
connect a remote switch to activate this feature on one or multiple dimmers for use as a
"maintenance light switch." Multiple dimmers are likely already sharing a common for their
DMX and/or Analog inputs, so a wire would only need to be added to terminal 12. Also, keep
in mind that this input can be useful in troubleshooting the lighting system.

Control

Starting Channel

The starting channel is set on a thumbwheel switch. When the switch reads 001, the dimmer
pack runs on DMX channels 1 - 4. Setting 005 runs on channels 5 - 8, setting 009 runs on
channels 9 – 12, and so on. Valid addresses range from 001 to 509 (512 for the DM124). The
starting dimmer may be any channel, and dimmers on different packs can overlap some
channels, though it is usually preferred to run them one dimmer per channel. Dimmer
WALL MOUNT SHOEBOX - USER MANUAL
8