2:
Product assembly continue
Step 3:
Check after crimping
Check appearance and pulling force after crimping terminals. The appearance must not be deformed. For details,
see lPC620. The pulling force should be measured according to the tension value corresponding to the actual wire
diameter, which should not be lower than the requirement of tension value in Table 2.
Step 4:
Install contacts
As shown in Figure 3, insert the crimped terminal and cable from the end of the connector according to the holes
required by the customer. lf you hear a click, the terminal is installed in place. Gently pull the cable and ensure that
the terminals are properly installed.
PIN CONTACT
Conductor
AWB
20AWG
0.519 mm
18AWG
0.823 mm
16AWG
14AWG
12AWG
10AWG
5.261 mm
RECEPTACLE
Table 2
Pulling force
mm
Pounds
2
13
2
20
2
1.31 mm
30
2
2.08 mm
50
2
3.31 mm
70
2
80
2
Figure 3
N
57.9
89.0
133.5
222.5
311.5
356.0
SOCKET CONTACT
PLUG
6