5.2
Counting modes main counter and totalizer (input mode)
Counting input Track A,
reversal Track B (Up/
Down)
The adding and/or subtrac-
ting count directions are
automatically set when se-
lecting the operating mode
in programming line 21
(diagram for adding mode).
If necessary, it is possible
to use the entry Track B for
reversal of direction count.
Programming line 30 to
digit 0.
Differential counting
Track A adding and Track
B subtracting (A-B)
Signal duration and
particular time at choice.
Programming line 30 to
digit 1.
Totaling Track A adding
and Track B adding (A+B)
The adding and/or subtrac-
ting count directions are
automatically set when se-
lecting the operating mode
in programming line 21.
Programming line 30 to
digit 2.
Up/down count with
two counting signals by
90° out of phase
The count direction is
automatically recognized
on the basis of the 90°
leading or trailing phase
shift. The internal phase
discriminator does the
evaluation. Single, double
or quadruple evaluation is
possible. Programming line
30 to digits 3, 4 or 5.
40