10
Technical data
10
Technical data
10.1
Technical data - electrical ratings
Voltage supply:
•
Consumption w/o load:
•
Initializing time:
•
Interfaces:
•
Function:
•
Transmission rate:
•
Profile conformity:
•
Device adress:
•
Steps per turn:
•
Number of turns:
•
Additional output signals:
•
Sensing method:
•
Code:
•
Code sequence:
•
Inputs:
•
Interference immunity:
•
Emitted interference:
•
Programmable parameters:
•
Diagnostic function:
•
Status indicator:
•
Approvals:
•
39
9...30 VDC
≤100 mA (per interface SSI)
≤250 mA (per interface bus)
≤200 ms after power on
SSI, Profibus-DPV0, CANopen®, DeviceNet
Multiturn
9.6...12000 kBaud (Profibus)
10...1000 kBaud (CANopen®)
125...500 kBaud (DeviceNet)
Profibus-DPV0
CANopen® CiA DSP 406 V 3.0
Device Profile Encoder V 1.0
Rotary switch in bus cover
8192 / 13 bit
≤65536 / 16 bit
Square-wave TTL (RS422)
Square-wave HTL
Optical
Gray (version SSI)
CW default
SSI clock (version SSI)
EN 61000-6-2
EN 61000-6-3
Depending on the selected absolute interface
Position or parameter error
DUO-LED integrated in bus cover
CE, UL approval / E256710
Baumer_AMG11-B3_DE_EN_202010_MI_11127402 (20A1)