Dover BLACKMER CRL1.25 설치, 작동 및 유지보수 지침 - 페이지 2

{카테고리_이름} Dover BLACKMER CRL1.25에 대한 설치, 작동 및 유지보수 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Dover BLACKMER CRL1.25 12 페이지. Blackmer liquefied gas pumps

Dover BLACKMER CRL1.25 설치, 작동 및 유지보수 지침
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Hazardous
machinery can
cause serious
personal injury.
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury or property damage.
Hazardous pressure
can cause serious
personal injury or
property damage
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
Hazardous or toxic
fluids can cause
serious injury.
PUMP IDENTIFICATION
A pump Identification tag, containing the pump serial number, I.D. number, and model designation, is attached to each pump. It is
recommended that the data from this tag be recorded and filed for future reference. If replacement parts are needed, or if
information pertaining to the pump is required, this data must be furnished to a Blackmer representative.

TECHNICAL DATA

Models
Maximum Pump
Speed
Minimum Operating
Temperature
Maximum Operating
Temperature
Maximum Differential
Pressure
Maximum Working
Pressure
Technical Data is for standard materials of
construction. Consult Blackmer Material Specs for
optional materials of construction.
SAFETY DATA

PUMP DATA

CRLR1.25
CRL1.25, CRL1.5
1,150 RPM
1,150 RPM
-30°F
-30°F
(-34°C)
(-34°C)
240°F
240°F
(115°C)
(115°C)
70 psi
100 psi
(4.8 Bar)
(6.9 Bar)
525 psi
525 psi
(36.2 Bar)
(36.2 Bar)
701-A00
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Hazardous voltage.
Can shock, burn or
cause death.
Failure to relieve system pressure prior
to performing pump service can cause
serious personal injury or property
damage. Systems with meters will still
be pressurized even after the hose is
Hazardous pressure
emptied
can cause serious
personal injury or
property damage
Operation without guards in place can
cause serious personal injury, major
property damage, or death.
Do not operate
without guard
in place

INITIAL PUMP START UP INFORMATION

Model No.: ____________________________________
Serial No.: ____________________________________
ID No.: _______________________________________
Date of Installation: _____________________________
Inlet Gauge Reading: ____________________________
Discharge Gauge Reading: _______________________
Flow Rate: _____________________________________
page 2/12