WARNING
DISCONNECT THE ELECTRICITY SUP-
PLY BEFORE ANY MAINTENANCE OPE-
RATION.
Dangerous voltage.
Can cause
injury and death
.
WARNING
HANDLING THE PUMP WITHOUT THE
COVER IN PLACE MAY CAUSE BODILY
HARM, SERIOUS INJURY OR EVEN
DEATH.
Do not operate
without guard
in place.
4.1 Replacing the hose
4.1.1 DISASSEMBLING THE HOSE
Close the inlet and discharge valves, purge the pipes.
Disconnect the pump from inlet and discharge piping.
To insure an optimal life cycle of the hose, it is recom-
mended to replace the worn lubricant by some new
lubricant during any replacement of hose.
The hose may contain a certain volume of the pumped
fluid, but this will be expelled when restarting the pump.
Evacuation of this fluid may also be carried out by run-
ning the pump after having taken all the safety measu-
res required for personal and property protection.
If maintenance of the pump is not carried on site, check
the wheel rotation direction to determine the inlet and
discharge ends.
If the pump is equipped with the "leak detection kit",
which allows the pump to be stopped in the event of the
hose breaking, first the capacitive sensor must be removed
by unscrewing the large PVC ring. See the kit Instructions
for further information.
Drain the lubricant by unscrewing the level plug 33 and
collect the lubricant in a tub.
Put the lubricant level plug 33 back in place.
Retighten cover screws 33 until they make contact.
NT 1101-C00 08.10 A20 - AS20 e
4. MAINTENANCE OPERATIONS
NOTES
WARNING
Hazardous or toxic
fluids can cause
serious injury.
WARNING
Hazardous pressure
can cause
personal injury
or property damage.
Free the space as required and explained in § PUMP
LOCATION.
Remove circlips 24 from the suction and discharge
ports.
Loosen and remove screws 48 with their washers 49
and remove brackets 18 from the suction and discharge
ports.
Loosen inlet and discharge clamps 7 and 9.
Remove the 2 inserts 12.
Place a tub under the lower port so that the lubricant in
the pump is collected.
9/16
IF PUMPING HAZARDOUS OR TOXIC
FLUIDS, THE SYSTEM MUST BE FLUSHED
PRIOR TO PERFORMING ANY SERVICE
OPERATION.
HYDRAULIC PRESSURE MUST BE FULLY
RELEASED BEFORE MAINTENANCE
OPERATIONS IN ORDER TO PREVENT
PERSONAL INJURY OR PROPERTY
DAMAGE.