Amphenol Temposonics GH 간단한 지침 - 페이지 11
{카테고리_이름} Amphenol Temposonics GH에 대한 간단한 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Amphenol Temposonics GH 12 페이지. Linear position sensor analog and digital pulse outputs
Amphenol Temposonics GH에 대해서도 마찬가지입니다: 사용자 설명서 (8 페이지)
LED
5.1 Analog
D60
M16 connector
Pin
1
2
6
5
3
4
View on sensor
HXX / RXX
Cable
Color Function
GY
PK
YE
GN
BN
WH
Analog LED status
Green
Red
Information
ON
OFF
Normal function
ON
ON
Magnet not detected
Flashing
OFF
Serial programming mode
Manuals, Software & 3D models
available at: www.mtssensors.com
Outputs
• Analog
• Start / Stopt
Function
1
Position
2
DC Ground
3
USB programmer
4
USB programmer
5
+24 VDC (−15 / +20 %)
6
DC Ground (0 V)
Position
DC Ground
USB programmer
USB programmer
+24 VDC (−15 / +20 %)
DC Ground (0 V)
5.2 Start / Stop
D60
M16 connector
Pin
1
2
6
5
3
4
View on sensor
HXX / RXX
Cable
Color Function
GY
PK
YE
GN
BN
WH
Start/Stop LED status
Green
Red
Information
ON
OFF
Normal function
ON
Flashing Missing external start signal
ON
ON
Magnet not detected
Flashing
OFF
Serial programming mode
I
11
I
Temposonics
G-Series
®
Brief Instructions
Function
1
Stop (−)
2
Stop (+)
3
Start (+)
4
Start (−)
5
+24 VDC (−15 / +20 %)
6
DC Ground (0 V)
Stop (−)
Stop (+)
Start (+)
Start (−)
+24 VDC (−15 / +20 %)
DC Ground (0 V)