G-Series Wiring/Connections
Table 1 - Analog Output Connections (Voltage or Current)
Integral cable
Integral
wire color
connector
_ _
R_ _ or F
D60 pin no.
Gray
Pink
Yellow
Green
Red or Brown
White
---
---
---
---
---
---
---
---
Table 2 - Digital Pulse Output Connections (Start/Stop or PWM)
Integral cable
wire color
R_ _ or F_ _
D60 pin no.
Gray
Pink
Yellow
Green
Red or Brown
White
---
---
---
---
Table 3 - Square Wave Neuter Output Connections
The G-Series square wave neuter
output is provided for backwards
compatibility to replace Tempo I,
Tempo II, and L-Series sensors.
These sensors have the neuter
output option for connection to the
Analog Output Module (AOM),
Digital Interface Box (DIB), or to
custom interfaces/controllers.
Reference the G-Series Cross
Reference, part no. 550967, for
additional neuter output connection
information, including adapter
cables and field-installed connec-
tors.
In-line
connector
RB_ pin no.
1
4
2
3
3
7
4
8
5
5
6
1
2
6
9
10
Integral
In-line
connector
connector
RB_ pin no.
1
3
2
4
(and 8)
3
9
4
10
5
5
6
1
---
2
---
6
---
7
---
---
Integral cable
Integral
wire color
connector
R_ _ or F_ _
D60 pin no.
Gray
1
Pink
2
Yellow
3
Green
4
Red or Brown
5
White
6
---
---
---
---
---
---
In-line
connector
.
Function (Note 1)
FM_ pin no
0 to 10, -10 to +10 Vdc, or
4 to 20 mA, 0 to 20 mA
D
or reverse acting (note 2):
10 to 0, +10 to -10 Vdc, or
20 to 4 mA, 20 to 0 mA
C
Return for pin 1
G
Programming (RS-485 +)
H
Programming (RS-485 -)
E
Supply voltage (+Vdc)
A
DC ground (for supply)
B
No connection
F
No connection
J
No connection
K
No connection
In-line
connector
FM_pin no
C
(-) Gate for PWM
(-) Stop for Start/Stop, or
Programming (RS-422 TX -)
D
(+) Gate for PWM
(+) Stop for Start/Stop, or
Programming (RS-422 TX +)
J
(+) Interrogation for PWM (see note)
(+) Start for Start/Stop, or
Programming (RS-422 RX +)
K
(-) Interrogation for PWM (see note)
(-) Start for Start/Stop, or
Programming (RS-422 RX -)
E
Supply voltage (+Vdc)
A
DC ground (for supply)
B
No connection
F
No connection
G
No connection
H
No connection
In-line
connector
Function
RB_ pin No.
(see note 1)
3
(-) Stop (note 2), or
Programming (RS-422 TX -)
8
(+) Stop (Compatible
(and 4)
Neuter Output Pulse), or
Programming (RS-422 TX +)
9
(+) Start (note 3, 4), or
Programming (RS-422 RX +)
10
(-) Start (note 3, 4), or
Programming (RS-422 RX -)
5
Supply voltage (+Vdc)
1
DC ground (for supply)
2
No connection
6
No connection
7 (note 5)
No connection
2
Notes:
1. The format used to show the voltage
2. If the G-Series sensor is replacing a
Note:
Function
When using PWM output with internal
interrogation both of the interrogation
input signals are not used, and can be
left unconnected or connected to
ground.
Notes:
1. The "(+) Stop" output is used for a compatible square wave
neuter signal.
2. The G-Series output signal, "(-) Stop" is not used when
providing the backwards-compatible neuter type connection.
However, this signal wire / connector pin is used for "RS-422
TX-" during serial programming of the sensor. When the
sensor output is active, (not in programming mode), this signal
must be left unconnected to allow the proper neuter type
output.
3. When connecting to an Analog Output Module (AOM), or to a
Digital Interface Box (DIB), or to a custom interface/controller
that requires single-ended interrogation, always connect the
unused interrogation lead, "(+) Start" or "(-) Start", to ground at
the AOM/DIB/Controller.
4. For improved noise rejection when using external interrogation
use the positive and negative interrogation signals, "(+) Start"
and "(-) Start", to provide differential inputs to the sensor.
5. If pin 7 was originally used as DC ground for the Tempo II or
L-Series sensor being replaced then the DC ground connection
at the controller must be changed to use pin 1.
and current output range is: [Value at
Null (Setpoint 1)] to [Value at Span
(Setpoint 2)]. Not all of the available
outputs ranges for voltage are shown.
L-Series sensor where the reverse
acting outputs are being used then
the wire connections must be changed
at the controller. Refer to G-Series
Cross Reference, part no. 550967 for
details.