2. Installation (continued)
2.3 Battery Charger
The M-Series tester will also run off AC power supplied by the charger included in the test kit. To run the box of AC power or to charge the battery plug the charger
barrel plug into the charger port on the top of the test box and connect the charger to an AC Outlet.
2.4 AC Power Plug Adapter Connection / Replacement
The kits battery charger can be used on both 110 Vdc and 230 Vdc systems. For this reason, additional AC power plug adapters can be purchased (see
Accessories).
Use the following steps to change the power plug adapter:
1. Unplug the AC adapter from the wall and from the M-Series Tester. Firmly hold the AC adapter in one hand with the plug facing you.
2. With the other hand, press down on the plug adapter and slide upwards away from you.
To replace the AC power plug adapter:
1. Chose the correct adapter.
2. Slide the adapter plug against the adapter (There are grooves along the
channel for the adapter plug). Slide the adapter down until it snaps into place

2.5 Quick Start Instruction Label

A quick start instruction label is included in the test kit. The label is designed to fit flush on the backside of the M-Series analogue/PWM Tester.
• Remove dust and dirt from the surface of the backside.
• Align and apply the label smoothly on the backside of the tester and apply the label smoothly.
+5V
GND
ANA
PWM
− − − −
+12V
Note:
There is an arrow on the adapter to denote the way to slide the plug during
removal.
I
7
I
M-Series Tester
User's Manual