E
Bypass valve.
P
Pump plate.
P1
Mechanical seal bleed valve.
S
Mounting point for probe : M6 - threaded width : max. 8 mm.
V
Pump drain.
NT 1003-D00 09.12 AF HT e

1. OVERALL DIMENSIONS

3/18
Weight
Noise level
The sound level of a pump is greatly influenced by its condi-
tions of use. Cavitation and pumping products with high gas
contents generally increases the sound level.
Under the following pumping conditions :
• excluding cavitation
• discharge pressure : 5 bar
• speed of rotation 625 rpm
• product viscosity of 1 cSt
The sound level reached for the AF HT pump in good condi-
tions (ignoring the motor and gearbox noise) is less than
78 dB(A).
: 28 kg