Amphenol Procom PRO-ARU4G 사용자 설명서 - 페이지 4
{카테고리_이름} Amphenol Procom PRO-ARU4G에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Amphenol Procom PRO-ARU4G 10 페이지. 19” rack-mountable active receiver multicoupler
1 Preface
This user manual covers the Amphenol Procom Active Receiver Multicoupler models:
PRO-ARU4G and PRO-ARU8G.
In the subsequent chapters, for the sake of clarity:
Where the descriptions are valid for both receiver multicoupler models, the figure
in the model designation is replaced by "...", as example: PRO-ARU...G.
2 Safety precautions
2.1
Environment
The PRO-ARU...G is intended for indoor use only.
Do not allow the unit to be wet.
Do not operate the unit at temperatures outside the specified range -10 °C to +50 °C.
Do not place the unit in a corrosive environment.
2.2
Protective earth
The main earthing point is the center contact of the IEC60320-1 C14 mains power inlet.
(See chapter 4.2 and 4.3.2)
Connection to protective earth is provided via the 3-wire IEC mains power cord.
As safety relies on connection to protective earth,
the PRO-ARU...G must be connected to an earthed mains socket-outlet.
2.3
Equipotential bonding
It is strongly recommended that all interconnected conductive accessible parts in a
system are connected to an equipotential bonding system.
The center terminal of the 3 pole screw terminal block on the rear side is intended for
equipotential bonding. See chapter 5.4.
2.4
Fuses
Individual fuses are provided for both the mains voltage and the DC voltage.
The fuse holders are located on the rear side next to the supply voltage connectors.
On the top plate next to the fuse holders are marked the fuse specifications.
To maintain the safety level, a blown fuse must be replaced by a fuse of equal size,
type and value. Refer to chapter 7.1: "Spare parts".
2.5
Power on/off
No power on/off switch is provided on the PRO-ARU...G.
Therefore, as soon as power is connected, the equipment will be immediately active
and the green power on LED on the front plate will light, indicating power is on.
The mains power cord (mains plug or socket) serves as a mains switch and
either plug or socket of the cord must be easily accessible.
2.6
Reading this manual
Before installing or replacing of the PRO-ARU...G, this entire manual should be read
and understood. Incorrect installation and usage may damage the equipment.
This equipment is not suitable for use in locations
where children is likely to be present.
Page 4 of 10