AmpleNess S52100G 사용자 설명서 - 페이지 10
{카테고리_이름} AmpleNess S52100G에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AmpleNess S52100G 20 페이지. Storage lithium battery
4.4.2 Current Protection Function
Charging over-current protection
System stops charging if charging current is
over the protection value. Protection is
dismissed after a period of time. Please pay
attention that the maximum charging current
shouldn't exceed to the protection value
when using the battery.
4.4.3 Temperature Protection Function
Charging low/over-temperature protection
In
charging,
system
temperature protection and stops charging if
the battery temperature is over protection
range,
and
dismisses
temperature returns to rated hysteresis value.
4.4.4 Other Protection Function
System starts short circuit protection if it occurs to short circuit when battery starts working
from a shutdown state.
4.5 Running Environment
Running Environment
Working temperature
Relative humidity
Altitude
On-site environment
4.6 Storage
Battery storage should comply with the following:
1) When the battery is stored, it should be stored in the charged state of 40%~60%.
2) The battery should be stored in a clean, dry and ventilated room, avoid contact with
corrosive substances, and stay away from fire and heat sources. In the storage process, it is
prohibited to turn the battery upside down, and avoid mechanical impact and weight.
3) When the battery is not used for a long time, it is recommended to supplement the
power every six months or so. It can be charged for 1 to 2 hours by using a DC voltage
regulator charger by 0.2C current.
4) During maintenance, do not load or unload the battery cells in the battery by yourself;
otherwise, the performance of the battery will be degraded.
5) Do not disassemble or change any battery cells in the battery without authorization, and
do not dissect the battery.
AMPLENESS Lithium Battery S52100G User Manual
System stops discharging if discharging
current
Protection is dismissed after a period of time.
Please pay attention that the current required
by electrical equipment shouldn't exceed to
the protection value when using the battery.
Discharging low/over-temperature protection
starts
charging
In
temperature protection and stops supplying
electricity if the battery temperature is over the
protection
after
protection range, and dismisses protection after
temperature returns to rated hysteresis value.
Short circuit protection
Away from heat source, avoid direct sunlight, no corrosive gas, no
explosive gas, non-destructive insulation gas, non-destructive
insulation conductive dust.
8
Discharging over-current protection
is
over
the
discharging,
system
Condition
0℃ - 50 ℃
5% - 95%,no condensation
2000m
protection
value.
starts
discharging