Follett HCC1000WBS 설치 지침 매뉴얼 - 페이지 5
{카테고리_이름} Follett HCC1000WBS에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett HCC1000WBS 16 페이지. For ice storage bins. ice machine models with ride technology
Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m)
of ice machine in accordance with local and national codes. Outdoor
installation is not recommended and will void warranty.
2.1
2.1
Installation site requirements
➊
Electrical
• H_C1000(A/W)BS 208-230/60/1-15 amps
• H_E1000(A/W)BS 230/50/1-15 amps
(H_E1000A/W requires 15A circuit, 1.50 mm
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water fi ltration system (#00130286)
Condenser water supply for water-cooled systems
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
➍
Drain
• The drain line from the ice machine must have at least 1/4" per foot pitch (6,4mm/0,3m)
BIN • RIDE Technology
‡
H_E1000A/W
requires 15A circuit,
H_C1000A/W
2
1.50 mm
wire
‡
H_E1400A/W
requires 20A circuit,
2
4.00 mm
wire
H_C1400A/W
‡
2
wire)
➋
self-contained
NEMA
6-15
NEMA
6-20
• H_C1400(A/W)BS 208-230/60/1-20 amps
• H_E1400(A/W)BS 230/50/1-20 amps
(H_E1400A/W requires 20A circuit, 4.00 mm
➌
Site preparation
1/4" (6,4mm)
1' (0,3m)
‡
2
wire)
2
5