Follett HCC1010ABS 설치 지침 매뉴얼 - 페이지 9
{카테고리_이름} Follett HCC1010ABS에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett HCC1010ABS 17 페이지. Self-contained chewblet ice machine
Follett HCC1010ABS에 대해서도 마찬가지입니다: 매뉴얼 (8 페이지), 빠른 시작 매뉴얼 (8 페이지)
Connect utilities to louvered docking assembly.
6.1
Air-cooled ice machines only
➊
➋
➌
➏
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
➍
3/4" MPT x 1" slip
➎
1" Stand pipe/Drain
• Rough-in ice machine potable water
supply
➊
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
➎
.
pipe/drain
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Apply Petrol-gel to barbed drain fitting
• Replace access panel.
BIN • RIDE Technology
Minimum 8"
radius
➋
.
➌
.
➍
.
➏
self-contained
External connections
6.2
Water-cooled ice machines only
➊
➏
➋
➐
➑
3/4" barb x 3/4" FPT
➍
➎
• Rough-in ice machine potable water
supply
➊
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
pipe/drain
➎
.
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Connect cooling water supply
return
➐
• Apply Petrol-gel to barbed drain fitting
• Replace access panel.
6
➌
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
1" Stand pipe/Drain
➋
.
➌
.
➍
.
➏
and
➑
9