4 – Horizon ice tube runs - specifier guidelines
Long tube runs for RIDE remote ice delivery equipment
beverage
dispenser
ice transport tube –
1 3/16" OD,
2 1/8" OD with insulation
6
Form# 7040
Optional machine stand
22.00"
(55.9 cm)
25.50"
(64.8 cm)
support
maximum
straps
2' (60.9 cm)
minimum of
6" (15 cm)
turn/corner
radius
transport tube slope
(toward ice machine)
1/4"
(2 cm per meter)
6.88"
(17.5 cm)
A
C
B
D
A - 15.875" (40.3 cm)
C - 13.00" (33.0 cm)
B - 19.375" (49.2 cm)
D - 21.00" (53.3 cm)
1'
wall-mounted
ice machine
Remote 1650 series ice machine
Important specifier notes:
1. For secure wall mounting, specify
optional wall mount bracket.
2. Wall and fasteners must support the
weight of the ice machine, bracket,
supply water and ice. Use of a backing
board may be required with hollow
wall construction.
3. Machine stand mounting adds 6.88"
(17.5 cm) to height of ice machine.
4. No dips in tube routing allowed.
5. Ice transport tube needs minimum 1/4"
per foot (2 cm per meter) pitch toward
ice machine and should be secured to
prevent dips and traps from forming.
Important specifier notes:
1. 75' (22.8 m) maximum ice transport
tube run.
2. Tubing routing bends must have a
6.00" (15.2 cm) radius or larger.
3. If not supported from underneath,
secure insulated ice transport tube
at least every 2' (60.9 cm) to prevent
dips or traps.
4. Relative humidity levels above 80%
in areas where the ice machine or ice
transport tube are located may produce
excessive condensation that will cause
water damage.
5. Contact factory for recommendations
on running tubing through a decorative
soffit or chase.