Refrigeration charge
All service on refrigeration systems must be performed in accordance with all federal, state and local laws. It is the
responsibility of the technician to ensure that these requirements are met. Recharging ice machine to other than
factory specifications will void the warranty.
Ice machine charge specifications
HCE1010A
HCE1010W
HCE1410A
HCE1410W
HCC1010A
HCC1010W
HCC1410A
HCC1410W
HCC1010W Marine
HCC1410W Marine
Refrigerant replacement requirements
1. Non-contaminated refrigerant removed from any Follett refrigeration system can be recycled and returned to
the same system after completing repairs. Recycled refrigerant must be stored in a clean, approved storage
container. If additional refrigerant is required, virgin or reclaimed refrigerant that meets ARI standard 700-88
must be used.
2. In the event of system contamination (for example, a compressor burn out, refrigerant leak, presence of
non-condensibles or moisture), the system must be repaired, evacuated and recharged using virgin or
reclaimed refrigerant that meets ARI standard 700-88.
3. Follett Corporation does not approve of recovered refrigerants. Improper refrigeration servicing procedures
will void the factory warranty.
Evacuation
Evacuate the system to a level of 500 microns. When the 500 micron level is reached, close all valves. Allow the
system to sit for approximately 20 minutes. During this period the system pressure should not rise. If the system
pressure rises and stabilizes there is moisture in the system and further evacuation is needed. If the pressure
continues to rise check the system for leaks.
Ambients
Air temperature*
Water temperature
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
† Ambient water temperature is measured in the ice machine water reservoir.
Horizon Elite 1010/1410 Self-Contained (50 Hz and 60 Hz)
Charge
Refrigerant type
33 oz (936 g)
21 oz (595 g)
29 oz (822 g)
21 oz (595 g)
33 oz (936 g)
18 oz (510 g)
35 oz (992 g)
18 oz (510 g)
15 oz (425 g)
15 oz (425 g)
Minimum
50 F/10 C
100 F/37.8 C
45 F/7 C
90 F/32.2 C
R404A
R404A
R404A
R404A
R404A
R404A
R404A
R404A
R449A
R449A
Maximum
13