Follett HCE1410W 사용자 설명서 - 페이지 15
{카테고리_이름} Follett HCE1410W에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett HCE1410W 16 페이지. Ice machines (self-contained) 50 hz and 60 hz
Troubleshooting
Ice machine disposition
Legend:
ON
1.
Ice machine is in running
condition but not making ice.
2.
Machine in TIME DELAY without full
bin.
3.
Ice machine is not making ice.
HI AMPS.
.
4.
Ice machine is not making ice.
HI PRESSURE.
.
5.
Ice machine is not making ice.
Drain clog.
.
6.
Ice machine is making ice.
Drain clog.
.
Horizon Elite 1010/1410 Self-Contained (50 Hz and 60 Hz)
Possible causes
OFF
ON or OFF
1. Defective compressor.
2. Defective start relay.
3. Defective start capacitor.
4. Defective run capacitor.
5. Defective main contactor.
6. No output from PC board.
1. Ice jamming due to improperly
installed transport tube causing a
false shuttle.
2. Shuttle stuck in up position.
3. Damaged or improperly installed
thermostat (open).
4. Transport tube backed-out of
coupling.
1. Poor water quality causing ice to jam
auger.
2. Damaged shuttle mechanism.
3. Intermittent drive output from
PC board. Evaporator will freeze
causing a HI AMPS error.
4. Gearmotor is unplugged.
1. High ambient temperatures
>100 F (38 C).
2. Poor ventilation or air recirculation.
3. Clogged condenser (air-cooled).
4. No water flow through condenser
(water-cooled).
5. Fan not working properly. No
air flow.
• Blocked fan blades
• No fan output from PC board
• Faulty fan motor
1. Internal water leak touching chassis
sensor.
1. Improper flow in drain system.
Corrective action
FLASHING
1. Replace compressor.
2. Replace start relay.
3. Replace start capacitor.
4. Replace run capacitor.
5. Replace main contactor.
6. Replace PC board.
1. Correct transport tube routing.
2. Repair or replace shuttle
mechanism.
3. Replace or reposition thermostat.
4. Correct coupling installation.
1. Clean ice machine. Increase
flushing frequency. Position TDS
switch to High TDS setting.
2. Replace or repair shuttle
mechanism.
3. Replace PC board.
4. Plug in gearmotor.
1. Air condition area to below 100 F
(38 C).
2. Reposition ice machine or properly
ventilate. Prevent ice machine
exhaust from recirculating.
3. Clean condenser grille (air-cooled).
4. Restore water flow to condenser.
5. Correct air flow.
• Remove any blockage from fan
blades
• Replace PC board
• Replace fan motor
1. Identify and repair leak. Clean/dry
chassis and sensors and restart
machine.
1. Correct/clean drain system.
15