Follett HMC1410ABS 설치 지침 매뉴얼 - 페이지 5

{카테고리_이름} Follett HMC1410ABS에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett HMC1410ABS 17 페이지. Ice storage bins

Follett HMC1410ABS 설치 지침 매뉴얼

Prepare the installation site.

Provide drainage, water supply and electrical power to within 6 feet (2m)
of ice machine in accordance with local and national codes. Outdoor
installation is not recommended and will void warranty.
2.1
2.1
Installation site requirements
H_C1010A/W
requires 15A circuit,
1.50 mm
H_E1410A/W
requires 20A circuit,
4.00 mm
Electrical
• H_C1010/1410(A/W)BS 208-230/60
• H_E1010/1410(A/W)BS 230/50
(H_E1010A/W requires 15A dedicated circuit 1.50 mm
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water filtration system (item# 00130286)
• This equipment is to be installed with adequate backflow protection to comply with applicable
federal, state, and local codes
Condenser water supply for water-cooled systems
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
(3/4" Barb)
• Minimum 8" radius on silicone drain line. Drain line from the ice machine must have at least
1/4" per foot pitch (6,4mm/0,3m).
BIN • RIDE Technology
H_C1010A/W
NEMA
6-15
*
2
wire
H_D710A
2
wire
NEMA
5-15
H_C1410A/W
NEMA
6-20
(3/8" push-in internal connection, 3/8" OD tubing required)
self-contained
• H_D710ABS 115/60
Requires dedicated 15A circuit.
wire, H_E1410A/W requires 20A dedicated circuit 4.00 mm
2
(1/4" FPT inlet, 1/4" FPT outlet)

Site preparation

2 ft. x 1" OD
silicone tubing
and ttings
provided
1/4" per foot
(6,4 mm per 0,3 m)
wire)
2
2
5