Follett Horizon Elite Chewblet HCD1410NBS 매뉴얼 - 페이지 7

{카테고리_이름} Follett Horizon Elite Chewblet HCD1410NBS에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett Horizon Elite Chewblet HCD1410NBS 8 페이지. For drop-ins
Follett Horizon Elite Chewblet HCD1410NBS에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (16 페이지), 설치 지침 매뉴얼 (17 페이지), 매뉴얼 (8 페이지)

Follett Horizon Elite Chewblet HCD1410NBS 매뉴얼
5 – Horizon Elite ice tube runs - specifier guidelines
Long tube runs for RIDE remote ice delivery equipment
beverage
dispenser
minimum of
6.00" (15.24 cm)
turn/corner
ice transport tube –
1 3/16" OD,
2 1/8" OD with insulation

Remote condensing unit

Condensing unit installation specifications
Important specifier notes
1. Provide front, back and side clearances
as shown.
2. The maximum refrigerant line run length is
100' (30.5 m). Installations require 13-15 lb
of refrigerant depending on the line run.
3. The maximum line rise above the evaporator
is 35' (10.7 m). Condensing unit above
evaporator unit – 35' (10.7 m) (installations
with rise over 20' (6.1 m) require additional
suction line s-trap at midpoint rise).
4. The evaporator can only be mounted
a maximum of 15' (4.6 m) above the
condensing unit.
Note: The service loop is not included
when calculating length, rise or drop in the
tubing run.
Note: To connect evaporator/ice machine to rack systems, see page 3.
Remote 1010, 1410 series ice machine
support
maximum
straps
2' (60.9 cm)
radius
transport tube slope
(toward ice machine)
1/4"
1'
(2 cm per meter)
wall-mounted
ice machine
=
24.00"
(61.0 cm)
48.00"
(121.9 cm)
Important specifier notes
1. 75' (22.8 m) maximum ice transport
tube run.
2. Tubing routing bends must have a
6.00" (15.24 cm) radius or larger.
3. Dips and traps are not allowed. If not
supported from underneath, secure
insulated ice transport tube at least
every 2' (60.9 cm) to prevent drips
and traps.
4. Relative humidity levels above 80%
in areas where the ice machine or ice
transport tube is located may produce
excessive condensation that will cause
water damage.
5. Contact factory for recommendations
on running tubing through a decorative
soffit or chase.
air in
48.00"
(121.9 cm)
24.00"
(61.0 cm)
7
Form# 7035