Follett Horizon Elite Chewblet HCF1010RBS 설치 지침 매뉴얼 - 페이지 5

{카테고리_이름} Follett Horizon Elite Chewblet HCF1010RBS에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett Horizon Elite Chewblet HCF1010RBS 17 페이지. For drop-ins
Follett Horizon Elite Chewblet HCF1010RBS에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (16 페이지)

Follett Horizon Elite Chewblet HCF1010RBS 설치 지침 매뉴얼
Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2 m) of
ice machine in accordance with local and national codes. Outdoor installation
of low side is not recommended and will void warranty.
2.1
2.1
Installation site requirements
Electrical
• 120/60/1–5 amps
Potable water supply
• 10–70 psi (69–483 kpa)
• 45–90 F (7–32 C)
• Follett recommends the use of an in-line water filtration system (item# 00130286)
• This equipment is to be installed with adequate backflow protection to comply with applicable
federal, state, and local codes
Drain
(3/4" Barb)
• Minimum 8" radius on silicone drain line. Drain line from the ice machine must have at least
1/4" per foot pitch (6,4 mm/0,3 m).
Refrigeration lines
• 5/8" ∅ (15,8 mm) diameter suction line (insulated)
• 3/8" ∅ (9,5 mm) liquid line
DROP-IN • RIDE Technology
(3/8" push-in internal connection, 3/8" OD tubing required)
remote condensing

Site preparation

5/8" ∅ (15,8mm)
3/8" ∅ (9,5mm)
NEMA
5-15
1/4" per foot
(6,4 mm per 0,3 m)
2
2 ft. x 1" OD
silicone tubing
and ttings
provided
5