Follett Horizon Elite HCD1010R 설치 지침 매뉴얼 - 페이지 5

{카테고리_이름} Follett Horizon Elite HCD1010R에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett Horizon Elite HCD1010R 13 페이지. Remote condensing
Follett Horizon Elite HCD1010R에 대해서도 마찬가지입니다: 사용자 설명서 (17 페이지)

Follett Horizon Elite HCD1010R 설치 지침 매뉴얼
2.3
Electrical connections at contactor
Single Phase
POWER SUPPLY
230-60-1
Three Phase
POWER SUPPLY
230-60-3
2.4
Condensing unit refrigeration line-set connection point
(Tecumseh unit shown, but location is same for all units)
REMOTE CONDENSING UNIT
• Electrical disconnects required within 10' (3 m) for all hard wired
ELECTRICAL
DISCONNECT
• Install in accordance with NEC and local electrical codes.
L3
T3
L2
T2
L1
T1
GRD
COMPRESSOR CONTACTOR
NC AUXILIARY SWITCH
CRANK CASE
HEATER
• Electrical disconnects required within 10' (3 m) for all hard wired
ELECTRICAL
connections.
DISCONNECT
• Install in accordance with NEC and local electrical codes.
L3
T3
L2
T2
L1
T1
GRD
CRANK CASE
HEATER
connections.
COMPRESSOR
CONTACTOR
COMPRESSOR
CONTACTOR NC
AUXILIARY SWITCH
L1
L2
L3
T1
T2
T3
L1
L2
L3
T1
T2
T3
1010/1410:
5/8" suction
3/8" liquid
5