Monitor This page will allow you to monitor the current state of the Amplink device. The
app will always open to the Monitor page. The colored bars match the wire color of the
corresponding output on Amplink PDM. The output status is indicated by either a green
dot for ON, red dot for fault, or gray dot for OFF. There is nothing to tap or change on the
Monitor page.
Triggers In the Triggers page you can setup the input triggers. At least one trigger must
be active and set to "Voltage (+ve)" or "Ground (-ve)." If using multiple triggers select the
input signal they will respond to, choose either "Voltage (+ve)" or "Ground (-ve)". Any
unused triggers should be set to disabled.
Setup The Setup page is where you will make Changes to the output settings including;
output name, amperage limit, delay on, delay off, trigger logic (and/or). Tap the output
name to open the output configuration screen. Tapping <Back will save and exit the
configuration screen.
Name - tap the field to open the keyboard.
Amp limit - tap the field and scroll.
AND Triggers – tap and select from the list of active triggers
OR Triggers – tap and select from the list of active triggers
Delay On and Delay Off – tap and scroll to change the time, then tap "ok"
Test – tap to turn Output on or off, exiting the screen will turn off the output.
Trigger logic examples:
To setup all outputs to respond to an ignition trigger, select T1 in the "OR Triggers"
and leave "And Triggers" set to None.
Other Examples:
AND Trigger set to T1,T2 – the output will turn on when both Trigger 1 and Trigger 2
are activated.
OR Trigger set to T1,T2 – the output will turn on when either Trigger 1 or Trigger 2 is
activated.