Follett Symphony Plus 50 Series 설치 매뉴얼 - 페이지 7
{카테고리_이름} Follett Symphony Plus 50 Series에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett Symphony Plus 50 Series 17 페이지. Ice and water dispensers
Follett Symphony Plus 50 Series에 대해서도 마찬가지입니다: 매뉴얼 (6 페이지)
Installing wall mount dispensers
WARNING!
§ Wall mount dispensers are intended to be mounted
above a sink, eliminating the need for a drain pan.
§ Before beginning installation verify that the sink size
and location meet the requirements shown in Fig. 6.
§ If requirements are not met, a drain pan must be
used to prevent ice and water from falling on counter
or floor.
§ FAILURE TO TAKE THESE PRECAUTIONS
COULD RESULT IN SLIPS AND FALLS ON WET
FLOORS
Fig. 6 – Minimum sink requirements (without drain
pan), front view
Front View
Sink centered
below chutes
21.50"
(54.7 cm)
14.25"
(36.2 cm) min.
Fig. 7 – Minimum sink requirements (without drain
pan), side view
SIDE VIEW
24.36" (61.9 cm)
17.01"
(43.2 cm)
18.92"
(48.1 cm)
30.00" (76.2 cm)
MIN DISTANCE TO SINK FRONT
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
Front View
Sink centered
below dispenser
21.50"
(54.7 cm)
23.00"
(58.5 cm) min.
25HI425
35.88" (91.1 cm)
50HI425
39.88" (101.3 cm)
18.00" (45.7 cm)
SUGGESTED POWER
CORD ROUTING
7