Follett U300R400A/W 설치 매뉴얼 - 페이지 9

{카테고리_이름} Follett U300R400A/W에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett U300R400A/W 12 페이지. U300/ud300 series ice and beverage dispensers
Follett U300R400A/W에 대해서도 마찬가지입니다: 운영 매뉴얼 (17 페이지)

Installing U300/UD300 series dispenser in counter
All U300/UD300 dispensers must be installed level in both directions to ensure
!
proper operation and must be supported from below with supplied 6" (153mm) leg
accessory, or with channels installed at site. Do not hang dispenser on flange. These
dispensers weigh approximately 325 lbs (147kg). Use care when maneuvering unit
into position.
1. After determining that the dispenser location will meet all requirements detailed in this manual, cut counter for
slide-in or drop-in installation as shown in drawings below. Shaded area on drawings depicts slide in from rear
of counter, however dispensers may be slid into counter from any side.
2. If legs will be used, carefully block up dispenser and install set of 6" (153mm) legs.
3. For slide-in installations, carefully slide dispenser into position.
Plan view
U300 series single-sided dispensers
counter cut-out
Shaded area is additional cutout required for
slide-in installations only
38.5"
(978mm)
4. For drop-in installations only, rig dispenser for hoisting with a mechanical lift and carefully lower dispenser
into counter until dispenser rests on support blocks or legs. USE SPREADER BARS TO KEEP HOISTING
ROPES AWAY FROM UPPER SECTION OF DISPENSER. DO NOT HOIST BY TOWER OR RAIL
SECTION! MUST REMOVE HANDLE TO FIT IN COUNTER.
U300/UD300 series dispensers weigh approximately 325 lbs (147kg). Use of a
!
mechanical lifting device to lower dispenser into counter on drop-in installations is
strongly suggested to avoid injury.
5. Shim support members or adjust legs until dispenser flange rests lightly on counter.
DISPENSER MUST BE SUPPORTED SECURELY FROM BELOW. DO NOT HANG
!
DISPENSER ON COUNTER FLANGE.
6. Apply a bead approximately 1/4" (6mm) in diameter of NSF-listed silicone sealant (Dow Corning RTV-732 or
equivalent) around perimeter of dispenser where it meets counter and smooth sealant to a 1/8" (4mm) radius.
7. Install hard drain lines for all drains,
and insulate lines to prevent condensation.
DO NOT REDUCE DRAIN LINE SIZE. DO NOT TIE DRAINS TOGETHER.
!
PVC PIPE IS SUGGESTED. CARE MUST BE TAKEN IN SWEATING ANY ADJACENT
METAL DRAIN PIPE USED. EXCESSIVE HEAT APPLIED WHILE SWEATING METAL
PIPE MAY MELT PLASTIC FITTING ON DISPENSER.
8. Make electrical connections in accordance with applicable wiring diagrams on page 6 and chart on page 5, as
well as NEC and local codes. Provide disconnects within 10 ft (3m) of dispenser and icemaker for service
purposes.
Min.
33"
30.375"
(839mm)
(772mm)
flat
surface
maintaining at least a 1/4" per foot slope (6mm per 304mm run)
UD300 series dual-sided dispensers
counter cut-out
Dual-sided dispensers cannot be slid into counter unless
raised above counter. Call factory for details.
30.375"
42.5"
(772mm)
(1080mm)
38.5"
(978mm)
8
Plan view
11.625"
(296mm)
7.125"
(181mm)
11.625"
(296mm)
Min.
33"
(839mm)
flat
surface