Follett 15 Series 설치 매뉴얼 - 페이지 5
{카테고리_이름} Follett 15 Series에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Follett 15 Series 20 페이지. Ice and water dispenser
Water
WARNING!
Connect to potable water supply only.
§ Water Mineral Content:
– TDS: greater than 5 ppm (mg/l) but less than 400 ppm (mg/l)
– Hardness: Less than 200 mg/l (12 gpg)
§ Not recommended for use with softened water
§ Ingress Protection (IP) rating: IPX0 (no protection)
Clearances
§
CI/FS Models:
UD/UC Models: 3" (7.6 cm) behind dispenser for electrical and optional drain connection. 6" (153 mm) in
§
Electrical
115 V
§ 115 V, 60 Hz, 1 phase, 5A, maximum fuse 15A
§ Connect to dedicated 15A circuit, fuse or breaker
§ Must be grounded - requires 3-prong outlet. Do not remove ground.
230 V and 220 V
§ 230 V, 50 Hz, 1 phase, 5.5A or 220 V, 60 Hz, 1 phase, 5.5A
§ Connect to a dedicated circuit
§ Equipment ground required
§ Cord provided on ice machine
§ Replacement cord instructions, type IEC 60320-C13 attachment. If the supply cord is damaged, it must be
replaced by a special cord or assembly available from the manufacturer or its service agent.
Refrigeration
WARNING!
Do not damage the refrigerant circuit. Refrigerant can cause personal injury and/or damage dispenser.
§ Refrigerant
– 115 V: R134a – 5.0 ounces (142 grams)
– 230 V/220V: R134a – 7.2 ounces (204 grams)
Heat Rejection
§ 1700 BTU/hr (498 W)
3" (7.6 cm) behind and on each side of dispenser for electrical and connection and
ventilation
front of dispenser for ventilation.
Dispenser and Ice Machine - 115 V, 230 V, 220 V
5