Amprobe 2730785 사용자 설명서 - 페이지 10
{카테고리_이름} Amprobe 2730785에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Amprobe 2730785 17 페이지. Professional 1000a clamp meters
Display: 3-3/4 digits 4000 counts LCD display
Update Rate: 3 per second nominal
Polarity: Automatic
Power Supply: One 3V coin battery (ANSI/NEDA-5004LC, IEC-CR2032)
Power Consumption: ACD-6 PRO: 2.2 mA typical; ACD-6 TRMS-PRO: 2.8mA typical
Low Battery: Below approx. 2.4V
APO Timing: Idle for 30 minutes
APO Consumption: 40μA typical on all model functions except that 190μA typical on ACD-6
TRMS-PRO voltage & current functions
Environmental: Indoor operation; below 6,562ft (2000m)
Operating Temperature : 0°C to 40°C (32°F to 104°F) ; < 80% RH @ < 31°C; decreasing linearly
to 50% RH @ 40°C
Storage Temperature: -40ºF to 140ºF (-20ºC to 60ºC), < 80% R.H. (with battery removed)
Temperature Coefficient: nominal 0.15 x (specified accuracy)/ºC @ 0ºC to 18ºC or 28ºC to 40ºC
(32°F to 64°F or 82°F to 104°F)
Sensing: ACD-6 PRO – Average; ACD-6 TRMS-PRO – True RMS
Dimension: 224 x 78 x 26mm (8.8 x 3.1 x 1.1 in.)
Weight: 188 gm (6.7 oz)
Jaw opening & Conductor diameter: 45mm (1.77 in) max
Safety LVD: Meets IEC/EN/UL 61010-1 Ed. 3.0; CAN/CSA C22.2 No.61010-1-12 Ed. 3.0 to
Measurement Category III 600 V, class II, pollution degree 2; IEC/EN 61010-2-032 Ed. 3.0; IEC/
EN 61010-2-033 Ed. 1.0 and IEC/EN 61010-031 Ed. 1.1 (test leads).
�
EMC: Meets all applicable requirements in IEC/EN 61326-1. The instrument conforms
to CENELEC Low-voltage directive 2006/95/EC and Electromagnetic compatibility directive
2004/108/EC. However, electrical noise or intense electromagnetic fields in the vicinity of the
equipment may disturb the measurement circuit. Measuring instruments will also respond
to unwanted signals that may be present within the measurement circuit. Users should
exercise care and take appropriate precautions to avoid misleading results when making
measurements in the presence of electronic interference.
Electrical (23 °C ± 5 °C) < 75% RH
DC Voltage
Range
400.0 mV
4.000V, 40.00V, 400.0V
600V
NMRR: >50dB @ 50/60Hz
CMRR: >120dB @ DC, 50/60Hz, Rs=1kΩ
Input Impedance: 10MΩ, 30pF nominal (1000MΩ for 400.0mV Range)
Accuracy
± (1.0% rdg + 3d)
± (1.7% rdg + 3d)
± (2.0% rdg + 4d)
9