Amprobe ACD-3300 IND 사용자 설명서 - 페이지 11
{카테고리_이름} Amprobe ACD-3300 IND에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Amprobe ACD-3300 IND 17 페이지. Cat iv industrial true rms clamp meters
1.888.610.7664
Analog bar-graph: 28 times per second.
Operating environment: 0°C to 50°C (32°F to 122°F) at < 70% R.H.
Storage temperature: -20°C to 60°C (-4°F to 140°F) at < 80% R.H. with battery removed
from meter.
Temperature Coefficient: 0.1 × (specified accuracy) per °C. (0°C to 18°C, 28°C to 50°C).
Environmental: 2000m (6561.7 Feet), Indoor use.
Jaw opening capability: 57 mm (2.0 in) conductor.
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
Battery life: typically 75 hours with carbon-zinc; 150 hour with alkaline.
Dimensions:
ACDC-3400 IND: 281 x 108 x 53 mm (11.1 x 4.3 x 2.1 in.)
ACD-3300 IND: 279 x 103 x 53 mm (11 x 4.1 x 2.1 in.)
Weight:
ACDC-3400 IND: 559 gm ( 1.23 lb.)
ACD-3300 IND: 500 gm ( 1.10 lb.)
Safety: LVD Meets EN61010-1:2001 and EN61010-2-032:2002, CAT III 1000V, CAT IV 600V,
class II and pollution degree 2
EMC: EN 61326-1:2006 This product complies with requirements of the following
European Community Directives: 2004/108/EC (Electromagnetic Compatibility) and
2006/95/EC (Low Voltage) as amended by 93/68/EEC (CE Marking). However, electrical
noise or intense electromagnetic fields in the vicinity of the equipment may disturb the
measurement circuit. Measuring instruments will also respond to unwanted signals that
may be present within the measurement circuit. Users should exercise care and take
appropriate precautions to avoid misleading results when making measurements in the
presence of electronic interference.
Electrical
Accuracy: Stated accuracy at 23°C ± 5°C, < 75% RH
DC VOLTS
Ranges
660.0 mV, 6.600 V, 66.00 V, 660.0 V,
1000 V
Input impedance: 660 mV: >100 MΩ; 6.6 V:10 MΩ; 66 V to 1000 V: 9.1 MΩ
Overload protection: 1000 VDC or 750 VAC rms
AC VOLTS TRUE RMS
Ranges:
frequency
660.0 mV
50 to 100 Hz
6.600V, 66.00V
50 to 500 Hz
660.0V, 750V
50 to 500 Hz
Frequency **
50 to 1 kHz
www.calcert.com
15
10
20
5
25
0
30
Accuracy
± (0.5% rdg + 2 dgts)
Accuracy
± (1.5% rdg + 8 dgts)
± (1.5% rdg + 8 dgts)
± (1.5% rdg + 8 dgts)
± (0.1% rdg + 5 dgts)
10