Ambients
Intended for indoor use where ambient temperature does not exceed 104 F (40 C) and ambient relative humidity
does not exceed 65% RH .
Clearances
The top of the unit must have 15 inches of clear space above the freezer to ensure proper ventilation of the
refrigeration system .
The back of the freezer should have 2 inches of clearance to allow for power cord clearance and ventilation on unit .
Electrical Specifications
§ 115 V, 60 Hz, 1 phase
§ Minimum circuit ampacity: 20A
§ Maximum size of branch circuit overcurrent device: 20A circuit
§ Follett Products LLC recommends circuit be protected by GFCI breaker
§ Requires a dedicated circuit
Refrigeration Specifications
§ Refrigerant R290
§ FZR25: 3 .9 oz