Fault Log screen (picture 7), shows the count of faults which have occurred since the last time the fault
log was cleared. Some faults correspond to analog values shown on other screens, some correspond to
interlock switches connected to various components of the amplifier and other hardware and software
errors. See appendix and appendix for detailed explanations.
Picture 8: Elapsed Time Meters Screen
Elapsed Time Meters screen (Picture 8) shows the following information:
Total time unit on – Total Time the unit has been in powered on.
•
Total time in operate – Total Time the unit has been in OPERATE (high voltages on).
•
Total time main uptime – The main control board is powered whenever the prime power input is
•
connected to AC power. This timer measures total time the main control board was powered.
Main boot up count – This counter is incremented each time the main control board is powered
•
on, meaning essentially each time the prime power input is connected to AC power.
Power up count – This counter is incremented each time the unit goes from POWER OFF to
•
STANDBY.
Operate count – This counter is incremented each time the unit turns on high voltages (even, if
•
there is a fault and it goes to reset immediately).
Power on time – Time since last power on.
•
Picture 7: Fault Count Screen
Page 7 of 13
Picture 9: Temperature Screen