Amprobe ACD-6 Pro 사용자 설명서 - 페이지 7

{카테고리_이름} Amprobe ACD-6 Pro에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Amprobe ACD-6 Pro 16 페이지. Professional 1000a clamp meters
Amprobe ACD-6 Pro에 대해서도 마찬가지입니다: 사용자 설명서 (17 페이지)

Amprobe ACD-6 Pro 사용자 설명서
6
Diode test function
Inputs are made through the test leads terminals. Place slide-switch to # position.
Press SELECT button momentarily 2 times to select
Diode test function. Normal
forward voltage drop (forward biased) for a good silicon diode is between 0.400V to
0.900V. A reading higher than that indicates a leaky diode (defective). A zero reading
indicates a shorted diode (defective). An OL indicates an open diode (defective).
Reverse the test leads connections (reverse biased) across the diode. The digital
display shows OL if the diode is good. Any other readings indicate the diode is resistive
or shorted (defective).