Amprobe TIC 300 PRO 사용자 설명서 - 페이지 9
{카테고리_이름} Amprobe TIC 300 PRO에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Amprobe TIC 300 PRO 15 페이지. Meet the new standard in non-contact, high voltage detection
Amprobe TIC 300 PRO에 대해서도 마찬가지입니다: 사용자 설명서 (18 페이지), 빠른 시작 매뉴얼 (4 페이지)
Find Quality Products Online at:
OPERATION
ON/OFF Button
When the TIC 300 PRO is activated, the blue LEDs and
beeper will pulse at a slow rate about twice a second.
The red LED of the range (HIGH) will turn ON.
TEST Button
The TEST button should be used prior to testing actual
power circuits. The TEST function will cause the blue
LEDs and beeper of the range selected (LOW or HIGH) to
pulse at a fast rate.
OSHA listed clearance distances for working with
voltage. National or local requirements may be
different.
Line voltage (kV)
Phase to ground
phase to phase
(ft-in)
(m)
0.03 to 1.0
Note1
Note1
1.1 to 15.0
2-1
0.64
15.1 to 36.0
2-4
0.72
36.1 to 46.0
2-7
0.77
46.1 to 72.5
3-0
0.90
72.6 to 121
3-2
0.95
Note1 – No contact necessary
�Caution: If a three phase circuit is being checked and
one phase is open, the voltage from another phase
maybe detected and will give a faulty indication. Always
make sure that the phase cables are separated by at least
20 in (50.8 cm).
5
GlobalTestSupply
www.
Phase to phase
(ft-in)
(m)
Note1
Note1
2-2
0.66
2-7
0.77
2-10
0.77
3-6
1.05
4-3
1.29
.com