Cardax Prox Mifare Series 설치 참고 사항
{카테고리_이름} Cardax Prox Mifare Series에 대한 설치 참고 사항을 온라인으로 검색하거나 PDF를 다운로드하세요. Cardax Prox Mifare Series 19 페이지. Teardrop
Cardax Prox Mifare Series에 대해서도 마찬가지입니다: 설치 참고 사항 (13 페이지)
Prox Mifare Series (Teardrop)
Before you Begin
Unpack the Prox Mifare Series (Teardrop) reader and check the shipment
contains the following items:
• 1 x Prox Mifare Series (Teardrop) reader base
• 1 x Prox Mifare Series (Teardrop) reader facia
• 1 x printed circuit board (PCB) assembly
• 1 x cable assembly
• 1 x M3 Torx Post Security screw
• 4 x self tapper pozi counter sunk fixing screws (two different lengths)
WARNING: You must use the screws provided, as using other types of
screws could interfere with the electronics. (See the "Mounting" section
later for further explanation.)
Power Supply Requirements
Power for the Prox Mifare Series (Teardrop) reader is usually taken from the
incoming supply of the device to which it is connected. That is, from the:
• Cardax FT Reader I/O Interface
• Cardax FT Controller 3000
• Cardax FT Universal Reader Interface (Cardax FT URI)
• Cardax Commander Universal Reader Interface (Cardax Commander URI).
The supply at the reader should be 13.6 V DC ± 15%. The current draw is 180
mA per reader. This is in addition to the requirements of any other device (for
example, the URI) powered from the same supply.
Part number 3E1100 R12
June 2007
This equipment contains components that can be damaged by
electrostatic discharge. Ensure both you and the equipment are
earthed before beginning any servicing.
Installation Note
CAUTION
1