Daikin 3MKS50E2V1B 설치 매뉴얼 - 페이지 16

{카테고리_이름} Daikin 3MKS50E2V1B에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Daikin 3MKS50E2V1B 20 페이지. R410a split series

Daikin 3MKS50E2V1B 설치 매뉴얼

Night Quiet Mode Setting

• If night quiet mode is to be used, initial settings must be made when the unit is
installed.
Explain night quiet mode, as described below, to the customer, and confirm
whether or not the customer wants to use
night quiet mode.
About night quiet mode
The night quiet mode function reduces operating noise of the outdoor unit at night-
time. This function is useful if the customer is worried about the effects of the oper-
ating noise on the neighbors.
However, if night quiet mode is running, cooling/heating capacity will be saved.
Setting procedure
Remove the SW5 jumper switch.
Once the settings are complete, reset the power.
NOTE:
Install the removed jumper switch as described below. This switch will be needed
to later disable this setting.
Jumper switch
COOL/ HEAT Mode Lock <S15>
(Heat Pump Units Only)
• Use the S15 connector to set the unit to only cool or heat.
Setting to only heat (H): short-circuit pins 1 and 3 of the connector <S15>
Setting to only cool (C): short-circuit pins 3 and 5 of the connector <S15>
The following specifications apply to the connector housing and pins.
JST products
Housing:
Pin:
Note that forced operation is also possible in COOL/HEAT mode.
■English
After removing
VHR-5N
SVH-21T-1,1
Service PC-board
Night Quiet Mode
setting switch (SW5)
COOL mode (C)
HEAT mode (H)
5<C>3<H>1
PCB
Allow view