AIRSLED AM2201 소유자 매뉴얼 - 페이지 3
{카테고리_이름} AIRSLED AM2201에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AIRSLED AM2201 8 페이지. Standard & heavy-duty appliance mover
POSITIONING THE AIR BEAMS
•
Appliance Mover air beams are 1/8" thick. There must be enough clearance between the floor and the
load's base to allow the air beams to be freely slid into place. DO NOT force the air beams under the
load.
•
If the gap between the air beam and load's base is greater than 1 ½", the air beams may not produce
the necessary lift. To address this issue, Airsled offers SPACER STICKS and ADJUSTABLE
SPACER SYSTEMS. More information on these items can be found on www.Airsled.com. Wood
blocking can also be used to bridge the gap.
•
Slide the air beams under the load. See figure 1.
•
Placement of the air beams will generally be done either through front or side access. See figure 2 &
3. Optimal Airsled performance will be achieved by centering the air beams under the load so that the
same length of air beam extends from the front as well as the back. Pushing the air beams as wide
apart as possible is also recommended.
Figure 1
•
The standard Appliance Mover air beams are 9" wide x 36" long and are recommended for loads
whose base does not exceed 32". If dealing with a load greater than 32" deep, Airsled offers a set of
9" wide x 39" long XL air beams. More information can be found on www.Airsled.com.
CONNECTING THE AIRSLED COMPONENTS
•
No tools are required to connect or disconnect the Airsled components. All connections between the
blower, lead hose, Tee connector, supply hoses and air beam inlets should be done by hand until a
snug fit. See figure 4.
NOTE: When connecting or
disconnecting the supply
hoses to the air beams, do so
by grabbing the:
Solid hose end
Solid plastic inlet
Pulling only the soft hoses
may damage your system.
Figure 2
Figure 4
70 – A Aleph Dr.
Support Email:
Toll Free Number: 1-800-AIRSLED (1-800-247-7533)
Newark, DE 19702
Page 2 of 7
Figure 3