• If the power cable is damaged, it must be replaced by the Customer Care Service or in
any case by specialised personnel, in order prevent any risk.
• The manufacturer declines any liability for damage or injury resulting from breach of the
above rules or non-compliance with the electrical safety regulations in force in the
country where the machine is used.
Electrical connection for appliances with plug
• To connect to the power supply, insert the power cable plug in the corresponding mains
socket, first making sure:
• the socket has an efficient earth contact and the mains voltage and frequency match
that given on the dataplate. In case of any doubts regarding the efficiency of the earth
connection have the system checked by specialised personnel;
• the system power supply is arranged and able to take the actual current absorption and
that it is correctly executed according to the regulations in force in the country of use;
• The plug must be accessible after positioning the appliance in the place of installation;
• The plug must be in a position always visible to the operator performing the intervention
during maintenance operations;
Electrical connection for appliances with cable without plug
• The connection point has an efficient earth contact and the mains voltage and frequency
match that given on the data plate. In case of doubts regarding the efficiency of the earth
wire, have the system checked by specialised personnel;
• the appliance must be permanently connected to the power supply, respecting the
polarities:
– brown/black/gray: phase
– yellow/green: earth
– blue: neutral;
• An H05VV-F type power cable (code 60227 IEC 53) is used for the permanent
connection to the mains; in case of replacement, use a type with at least these
characteristics. When replacing the cable, the earth wire must be kept longer than the
live and neutral wires.
• The differential thermal-magnetic switch must be lockable in the open position in case of
maintenance.
• If using a plug, it must comply with the national installation rules. The plug must also be:
– accessible after the appliance has been positioned
– in the place of installation;
– in a position always visible to the operator performing the intervention during
maintenance operations;
Positioning
• Install the appliance, taking all the safety precautions required for this type of operation,
also respecting the relevant fire-prevention measures.
W W A A R R N N I I N N G G
• Keep the ventilation openings in the appliance casing free of any obstructions.
Fitting anti-tipping cables on the glass door appliances with high feet
• When installing the glass door appliances with high feet make sure to fix the anti-tipping
cables to it.
• To fit proceed as shown in the paragraph F.5 Fitting anti-tipping cables